INSTALLATION &
OPERATION MANUAL
PWS1000
Power Supply
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)
www.analyticsystems.com
An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - PWS1000

INSTALLATION & OPERATION MANUALPWS1000 Power Supply8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884

Page 2

10Special Services & OptionsConformal Coating INCLUDED ON ALL UNITS UNLESS REQUESTED NOT TO as of April 1, 2014Option “c” Ruggedization Package (

Page 3

11Limited Warranty1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free from defects in workma

Page 4 - Specications

8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)www.analyticsystems.comAn ISO9001 and AS910

Page 5 - Installation

Copyright (2005-2013) Analytic Systems Ware (1993) Ltd.

Page 6 - Output Adjustment

3IMPORTANT & SAFETY INSTRUCTIONS1. SAVE THESE INSTRUCTIONS — This manual contains important safety and operating instructions for power supply.2.

Page 7 - Dry Contact Relay

4IntroductionAll new Current Mode switching design offers increased power and reliability in a compact package. Extra input and output ltering reduce

Page 8 - Remote Control Option

5GeneralInput Frequency 45 - 65 HzNoise on Input < 50 milli-VoltsNoise on Output < 50 milli-VoltsTransient Response < 1 V for 50% surgeEfcie

Page 9 - Troubleshooting

6OperationOutput AdjustmentTurn the switch on the top of the unit on to energize the outputs. The green indicator light will glow to indicate the prop

Page 10

7To use your dry contact output fail relay you must connect a 9-pin D connector to the unit. You must use pins one and six as is indicated on page 7

Page 11 - Limited Warranty

8A remote control panel may be connected to the converter using a 9-pin D-connector, which attaches to the side of the converter. The remote control

Page 12

9TroubleshootingThis unit provides LED indicators and a buzzer to help diagnose any problems. The unit should sound the buzzer to alert you prior to s